.

Wednesday, January 16, 2019

Collision Theory Essay

I draw been asked to inquire the effects different factors such as concentration and temperature nurse on the crop of reaction The consecrate of reaction is the loss rate of a reactant or the rate of creation of a product during a chemical reaction and it can be measured by dividing superstar by the time set outn for the reaction be completed.Collision opening states that an gain in concentration, temperature, surface area and the use of a catalyst in a reaction testament either increase the rate of reaction by increasing the rate of collision between reactant particles, increase the success rate of collisions between the reactants or both of these reactions, there is as well as another factor which effects the rate of reaction, but is only applicable in gasses, that factor being pressure.I have chosen to investigate the effects of Concentration on rate of reaction, as it is the most accurately achievable while still challenging factor to change. Method Equipment- 1x cone -shaped flask 2x 50ml criterion piston chamber 1x 10ml measure cylinder 1x pipette atomic number 11 Thiosulphate Hydrochloric acid Water Stop clock Safety look evident opus with a black cross on it. Add 10ml of HCL to a conical flask, by All procedures allow for be undertaken with safety goggles on.After assembling all of the equipment I will pour as close to 10 ml of hydrochloric acid into the 10 ml measuring cylinder, using the pipette to get the amount as close as reasonably possible, I will when doing this take into account surface tightness and hence fill so the actual amount in the measuring cylinder is at 10ml not a little under as it may appear. I will then furnish (starting with 50ml descending in steps of 5ml to 20ml) sodium thiosulphate to the 50ml measuring cylinder.Following this I will total (starting with 0ml rising to 30ml in steps of five, in such a trend that the total volume of water combined with sodium thiosulphate Is always at 50ml) water to the seco nd 50ml measuring cylinder. I will then add the two 50ml measuring cylinders contents into the cylinder containing the sodium thiosulphate, leave the cylinder for 10 seconds for the liquids to mix together (after swirling gently 10 times) before excretion the hydrochloric acid into the conical flask, followed by the mixture of sodium thiosulphate and water.The conical flask will be left on top of the piece of makeup for the addition of the latter and when the second liquid is poured into the conical flask the stage clock will be started, I will then maintain to watch the view the black cross on the piece of paper bellow the conical flask until the point I can no longer see the black cross, at which instance I will stop the stop clock and record the time taken on a table along with the volumes of liquids used, I will also take the temperature at the time to make sure if there is any study discrepancy caused by the temperature I will know that this is the case and will be able to identify and explain these results.

No comments:

Post a Comment